Dear Amber users
I am trying to perform membrane simulation of a GPCR using
DMPC bilayer. For that, I am trying to generate parameters
and partial atomic charges for a DMPC mononer using RESP
fitting integrated with antechamber.
DMPC momoner has a formal +1 (N atom) and -1 (P atom)
charge, and is thus overall neutral.
I generated the gaussian input file using antechamber, as
follows:
% antechamber –fi mol2 –i DMPC_mono_sybyl.mol2 –fo
gcrt –o DMPC_mono.com
Then, using the generated input file, I ran a gaussian job,
as follows:
% g03sub –n 1 DMPC_mono.com
Then I used the gaussian output in antechamber to do the
2-stage RESP fitting as follows:
% antechamber -rn DMP -fi gout -i H1DMPC_mono.out -fo prepi
-o DMPC_mono_resp.prep -c resp -s 2
This gave me the prep file, which I checked using PARMCHK
utility, as follows:
% parmchk -i DMPC_mono_resp.prep -f prepi -o
DMPC_mono_frcmod
The only warning I got in this frcmod was following:
IMPROPER
c3-o -c -os 10.5 180.0 2.0
General improper torsional angle (2 general atom types)
QUESTION: I am new to gaussian calculations and RESP
fitting. Although, I tried to follow the suggestions
closely, and seemingly the jobs have gone towards
completion.
1. I am wondering if there are places where I should look
to make sure if everything is in order?
2. Does the improper warning seems okay?
I look forward to your suggestions. Thanks in advance.
-Akshay Patny (Olemiss)
-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber.scripps.edu
To unsubscribe, send "unsubscribe amber" to majordomo.scripps.edu
Received on Sun Dec 24 2006 - 06:07:10 PST