AMBER: RE: Amber8: problem related to antechamber

From: priya priya <priyaanand_27.yahoo.co.in>
Date: Wed, 27 Sep 2006 04:49:34 +0100 (BST)

Dear Sir
   
  when we load a single peptoid residue in antechamber it appears in leap list but once we close leap and reopen it the residue loaded is missing in the list.
   
  With Regards
  Priya Anand

Junmei Wang <jwang.encysive.com> wrote:
  Besides Dave's comment, please bear in mind that the following message
is just for information, not a real error:

"The atom number exceeds the MAXATOM, reallocate memory"

Junmei


On Fri, Sep 22, 2006, priya priya wrote:
>
> I have a peptoid sequence (in peptoids the amino acid
> side chain is attached to the nitrogen instaed of
> carbon wrt proteins) of about 12-15 residues.
>
> I cannot load this molecule in antechamber.It says
> "The atom number exceeds the MAXATOM, reallocate
> memory".

Antechamber is designed to work with single residues at a time. You
should use it to create a unit for each peptoid residue you have, then
use LEaP to link them together into a polymer in the same way you would
for a regular protein.

...good luck...dac

-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber.scripps.edu
To unsubscribe, send "unsubscribe amber" to majordomo.scripps.edu


                                 
---------------------------------
 Find out what India is talking about on - Yahoo! Answers India
 Send FREE SMS to your friend's mobile from Yahoo! Messenger Version 8. Get it NOW
-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber.scripps.edu
To unsubscribe, send "unsubscribe amber" to majordomo.scripps.edu
Received on Wed Sep 27 2006 - 06:07:25 PDT
Custom Search