Dear Amber users:
If running two energy minimized calculations(AMBER 9),  and the only 
difference is based on igb=1 and igb=0  respectively.
My question is, why these two energy results were different not only in the 
EGB term but also slightly reflected in other energy terms.
Thanks for helping.
Sincerely.
backy
igb=1;
 NSTEP       ENERGY          RMS            GMAX         NAME    NUMBER
    100      -2.1822E+03     1.4027E+00     5.2406E+01     CD        946
 BOND    =       27.6833  ANGLE   =      110.3090  DIHED      = 
570.5037
 VDWAALS =     -474.1414  EEL     =    -4510.9973  EGB 
    =    -1095.9167
 1-4 VDW =      249.6525  1-4 EEL =     2759.7612  RESTRAINT  = 
180.9595
 EAMBER  =    -2363.1456
===================================================================================
igb=0;
 NSTEP       ENERGY          RMS            GMAX         NAME    NUMBER
    100      -1.3078E+03     1.2304E+00     2.4978E+01     CZ        887
 BOND    =       24.7837  ANGLE   =      103.8203  DIHED      = 
573.6811
 VDWAALS =     -499.1637  EEL     =    -4542.7328  HBOND      = 
0.0000
 1-4 VDW =      246.7077  1-4 EEL =     2755.1466  RESTRAINT  = 
29.9078
 EAMBER  =    -1337.7571
-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber.scripps.edu
To unsubscribe, send "unsubscribe amber" to majordomo.scripps.edu
Received on Sun Aug 13 2006 - 06:07:02 PDT