Thank you for your answer.
How I can keep then together? because as soon as the simulation start the
peptides start to unfold and to separate from each other.
Setting the distance between the petides > cutoff and rgbmas = cutoff could
resolve the problem???
Best regards
Anthony
On Friday 23 June 2006 12:09 pm, John Mongan wrote:
> You can't, but you don't need to. Since implicit solvent simulations are
> non-periodic, there is no problem with the system carrying a net charge.
> The saltcon moderates the strength of electrostatic interactions (weaker
> interactions with higher concentrations) -- it can't be used to
> neutralize charge as counter-ions are in an explicit solvent simulation.
>
> If you're planning to have two separate peptides in the same simulation,
> be aware that you may need to be careful to keep them together.
> Non-periodicity means that if they wander apart, they're unlikely to
> ever come back together.
>
> John
>
> Anthony Cruz wrote:
> > Hi User:
> > I have a little question. I planning to run a implicit solvent simulation
> > of two peptides. The total system charge is 6. How I can setup the
> > saltcon value to neutralize the total system charge????
> >
> > Best regards
> > Anthony
> >
> > -----------------------------------------------------------------------
> > The AMBER Mail Reflector
> > To post, send mail to amber.scripps.edu
> > To unsubscribe, send "unsubscribe amber" to majordomo.scripps.edu
>
> -----------------------------------------------------------------------
> The AMBER Mail Reflector
> To post, send mail to amber.scripps.edu
> To unsubscribe, send "unsubscribe amber" to majordomo.scripps.edu
-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber.scripps.edu
To unsubscribe, send "unsubscribe amber" to majordomo.scripps.edu
Received on Sun Jul 02 2006 - 06:07:12 PDT