AMBER: output of first stage RESP calculation

From: JunJun Liu <ljjlp03.gmail.com>
Date: Wed, 24 May 2006 19:23:55 -0300

Dear all,

I found the following information in the output of my first stage resp
fit. I know the first column is the atom serial number, but what do the
followed three digit stand for? Can anybody who knows please tell me?
Thanks!

===========================================
   there are 3 charge constraints:


      1 1 0 1
      2 1 0 1
      3 1 0 1
      4 1 0 1
      5 1 0 1
      6 1 0 1
      7 0 0 1
      8 0 0 1
      9 0 0 1
     10 0 0 1
     11 0 0 1
     12 0 0 1
     13 0 0 1
     14 0 0 1
     15 0 0 1
     16 0 0 1
     17 0 1 1
     18 0 1 1
     19 0 1 1
     20 0 1 1
     21 0 1 1
     22 0 1 1
=======================================

-- 
JunJun Liu
College of Chemistry
Central China Normal University
WuHan   430079
P.R. China
-----------------------------------------------------------------------