AMBER: a question about "solvateoct" in AMBER 8

From: Chengwen Chen <chenchengwen.gmail.com>
Date: Fri, 21 Apr 2006 14:48:14 +0800

Dear all,

I found out that the box size information listed in XLEAP after add the
solvent is different with that in ".inpcrd" file. Why ? Am I wrong? Which
one should I select to set the A, B, C parameters of PME box in the input
file? Thank you in advanced.

XLEAP information:
> solvateoct a TIP3PBOX 10.0
Scaling up box by a factor of 1.371926 to meet diagonal cut criterion
  Solute vdw bounding box: 34.115 45.712 32.074
  Total bounding box for atom centers: 73.150 73.150 73.150
      (box expansion for 'iso' is 46.1%)
  Solvent unit box: 18.774 18.774 18.774
  Volume: 203847.880 A^3 (oct)
  Total mass 107696.280 amu, Density 0.877 g/cc
  Added 5536 residues.

Last line in ".inpcrd" file:
64.2159170 64.2159170 64.2159170 109.4712190 109.4712190 109.4712190


Best Wishes,
Chengwen

-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber.scripps.edu
To unsubscribe, send "unsubscribe amber" to majordomo.scripps.edu
Received on Sun Apr 23 2006 - 06:07:08 PDT
Custom Search