AMBER: antechamber problem using RESP

From: <luckyang.gmail.com>
Date: Mon, 1 Aug 2005 20:29:26 -0500

Dear All,

I am trying to calculate the partial charge of CH4 using antechamber
with RESP option. I generated the Gaussian 03 input file with:

antechamber -i ch4.pdb -fi pdb -o ch4.com -fo gcrt

I got:

--Link1--
%chk=MOL
#HF/6-31G* SCF=tight Test Pop=MK iop(6/33=2) iop(6/42=6) opt

remark line goes here

0 1
    C 0.0000 -0.0000 0.0000
    H 1.0920 0.0000 0.0000
    H -0.3650 1.0290 0.0000
    H -0.3640 -0.5150 0.8920
    H -0.3640 -0.5150 -0.8920

This input file works well with Gaussian 03 and I got the ch4.log
file. But I get some problem with:
antechamber -i ch4.log -fi gout -o ch4.mol2 -fo mol2 -c resp -s 2

Here is the error message:

Running: /usr/softwares/amber8/exe/bondtype -i
ANTECHAMBER_BOND_TYPE.AC0 -o ANTECHAMBER_BOND_TYPE.AC -f ac -j full


Running: /usr/softwares/amber8/exe/atomtype -i ANTECHAMBER_AC.AC0
-oANTECHAMBER_AC.AC -p gaff


Running: /usr/softwares/amber8/exe/espgen -o ANTECHAMBER.ESP -i ch4.log



Running: /usr/softwares/amber8/exe/respgen -i ANTECHAMBER_RESP.AC
-oANTECHAMBER_RESP1.IN -f resp1


Running: /usr/softwares/amber8/exe/respgen -i ANTECHAMBER_RESP.AC
-oANTECHAMBER_RESP2.IN -f resp2


Running: resp -O -i ANTECHAMBER_RESP1.IN -o ANTECHAMBER_RESP1.OUT
-eANTECHAMBER.ESP -t qout


 Amber8 Module: resp

? FORTRAN Runtime Error:
? Attempt to read past end of file
? READ(UNIT=5,...
resp -O -i ANTECHAMBER_RESP2.IN -o ANTECHAMBER_RESP2.OUT -e
ANTECHAMBER.ESP -q qout -t QOUT


 Amber8 Module: resp

? FORTRAN Runtime Error:
? Attempt to read past end of file
? READ(UNIT=5,...
Cannot open charge file QOUT , exit

Does anyone know the source of this problem?

Many thanks,

Lu Yang
-----------------------------------------------------------------------