Re: AMBER: vlimit in heating

From: David A. Case <case.scripps.edu>
Date: Wed, 9 Mar 2005 08:10:42 -0800

On Wed, Mar 09, 2005, Gustavo Pierdominici Sottile wrote:

> Hi , I have written because as soon as I have started the heating, the
> problem of the vlimit appeared.
>
> group of rest
> 500.0
 ^^^^^^ this is very large; try something about 100 times smaller

> FIND
> CA CT * *
> SEARCH
> RES 1 476
> END
> END
> &cntrl
> irest=0, ntx=1, tempi=0.0, nmropt=1, ntr=1,
> ntt=1, tautp=2.5,ntb=0, cut=9.0, ivcap=0,
> nstlim=42000, ntwe=0, ntwx=4200, ntwv=0, ntpr=100,
      ^^^^^^^^^^^^ ^^^^^^^^^

When you have problems, set nstlim to 1000 or so, and ntpr=1. Then you
can look more carefully at what is happening.

....good luck....dac

-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber.scripps.edu
To unsubscribe, send "unsubscribe amber" to majordomo.scripps.edu
Received on Wed Mar 09 2005 - 16:53:00 PST