RE: AMBER: What PRESS is?

From: Ross Walker <ross.rosswalker.co.uk>
Date: Mon, 7 Mar 2005 20:07:37 -0800

Hi Hanjun,

Press is the pressure of your system. It will fluctuate wildly during a
simulation and so instantaneous values are not of much use. What you should
look at is the average pressure. Over a sufficiently long run this should
average out to +1 = 1 atmosphere.

All the best
Ross

/\
\/
|\oss Walker

| Department of Molecular Biology TPC15 |
| The Scripps Research Institute |
| Tel:- +1 858 784 8889 |
| EMail:- ross.rosswalker.co.uk |
| http://www.rosswalker.co.uk/ | PGP Key available on request |

Note: Electronic Mail is not secure, has no guarantee of delivery, may not
be read every day, and should not be used for urgent or sensitive issues.



> -----Original Message-----
> From: owner-amber.scripps.edu
> [mailto:owner-amber.scripps.edu] On Behalf Of hj zou
> Sent: 07 March 2005 19:01
> To: amber.scripps.edu
> Subject: AMBER: What PRESS is?
>
> Dear amber community,
> Could anyone tell me the meaning of PRESS in md.out
> file? I am wondering whether something is wrong as it has a
> big fluctuation as follows.
> NSTEP = 1300 TIME(PS) = 342.600 TEMP(K) = 302.08
> PRESS = -297.3
> Etot = -54301.9484 EKtot = 13568.1576 EPtot =
> -67870.1061
> BOND = 367.6443 ANGLE = 981.5511 DIHED =
> 1246.3807
> 1-4 NB = 469.0386 1-4 EEL = 5760.1071 VDWAALS =
> 8107.2579
> EELEC = -84802.0858 EHBOND = 0.0000 RESTRAINT =
> 0.0000
> EKCMT = 6001.1452 VIRIAL = 7418.4268 VOLUME =
> 220819.1849
> Density =
> 1.0136
> Ewald error estimate: 0.4016E-04
>
> --------------------------------------------------------------
> ----------------
>
>
> NSTEP = 1350 TIME(PS) = 342.700 TEMP(K) = 298.15
> PRESS = 118.4
> Etot = -54318.5088 EKtot = 13391.7411 EPtot =
> -67710.2499
> BOND = 403.3811 ANGLE = 968.5517 DIHED =
> 1238.8836
> 1-4 NB = 458.3685 1-4 EEL = 5741.6964 VDWAALS =
> 8271.1966
> EELEC = -84792.3280 EHBOND = 0.0000 RESTRAINT =
> 0.0000
> EKCMT = 5961.5216 VIRIAL = 5396.9719 VOLUME =
> 220748.7612
> Density =
> 1.0139
> Ewald error estimate: 0.3098E-04
>
> --------------------------------------------------------------
> ----------------
>
>
> Thank you in advance.
> Best regard,
>
> ***********************************************
> Hanjun Zou
> 555 Zu Chong Zhi Road, Zhangjiang Hi-Tech Park
> Drug Discovery and Design Center
> Shanghai Institute of Meteria Medica
> Chinese Academy of Sciences
> Shanghai 201203, China
> Tel: +86-21-50806600-1201
> E-mail: hjzou.mail.shcnc.ac.cn
> ***********************************************
>
>
>
> --------------------------------------------------------------
> ---------
> The AMBER Mail Reflector
> To post, send mail to amber.scripps.edu
> To unsubscribe, send "unsubscribe amber" to majordomo.scripps.edu
>

-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber.scripps.edu
To unsubscribe, send "unsubscribe amber" to majordomo.scripps.edu
Received on Tue Mar 08 2005 - 04:53:00 PST
Custom Search