Re: AMBER: A problem about Gaussian

From: David A. Case <case.scripps.edu>
Date: Thu, 3 Mar 2005 16:55:35 -0800

On Thu, Mar 03, 2005, Yanze Zhang wrote:
>
> I ran antechamber to get the gaussian input file. The command line was
> like this:
> #HF/6-31G* SCF=tight Test Pop=MK iop(6/33=2) iop(6/42=6) opt. But the
> molecule systmem I am studying is very huge. The polypeptide has 35
> residues and there are 253 atoms.

Generating RESP charges is almost universally done on small fragments, which
are then linked together to make larger molecules. If you are dealing with
a polypeptide, there should be no need to do this: charges are already
available in the Amber libraries for amino acids.

....good luck...dac

-----------------------------------------------------------------------