On Fri, Dec 17, 2004, MURAT CETINKAYA wrote:
>
> I am trying to establish some parameters for a single walled carbon
> nanotube.
>
> Leap wants an angle parameter for C-C-C bonds, so I used parmcal and got
> 65.690 and 120.000 as results. However, in the literature I found some
> values like 562 kJ/mol (=134 kCal/mol).
You should not necessarily assume that "C" is a good representative of a
carbon nanotube. Also be aware that Amber uses an energy function for angles
like this:
E = K * (delta-theta)**2
where delta-theta is measured in radians, and there is no factor of (1/2)
in the equation. Keep these in mind as you compare parameters, since the
literature functions may be different.
I doubt that any atoms one usually sees in biomolecules really looks much like
what one has in a nano-tube.
....good luck....dac
-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber.scripps.edu
To unsubscribe, send "unsubscribe amber" to majordomo.scripps.edu