Dear Youyi Peng,
> In a old poster 2002, you recommended a simple procedure to
> calculate
> RESP charges. This poster is followed. Now I also want to calculate
> RESP
> charges for a system consisting of several fragments which includes a
> Mg
> ion. I wonder if I can use this simple procedure to do the calculation
> or I
> have to go the traditional method. It seems antechamber doesn't
> recognize Mg.
We hope to release RED (
http://www.u-picardie.fr/labo/lbpd/RED/) this week...
We just checked and models which include Mg++ or Na+ ion are well handled...
Regards, Francois
F.-Y. Dupradeau
--
The Scripps Research Institute, San Diego, CA
Faculte de Pharmacie, UPJV, Amiens, France
--
http://www.u-picardie.fr/labo/lbpd/fyd.htm
-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber.scripps.edu
To unsubscribe, send "unsubscribe amber" to majordomo.scripps.edu
Received on Mon Nov 17 2003 - 22:53:00 PST