Re: Residual dipolar couplings

From: David A. Case <case.scripps.edu>
Date: Fri, 2 May 2003 10:21:53 -0700

On Wed, Apr 30, 2003, McAteer, Kathleen wrote:

> Has anyone else experienced problems reading residual dipolar coupling
> restraints in AMBER 7? My input file for RDCs is shown below:

>
> &align ndip=12, dcut=-1.0, gigj=-3.163, s11=-10.0, s22=-10.0, s12=0.0,
                               ^^^^^^^^^^^

The gigj variable needs to be set for *each* coupling (since they might not
all be the same). Hence you need something like:

  gigj=12*-3.163,

if you want all twelve of the observed values to have that value for gigj.
Since the default value is zero, for every coupling past the first one, you
would get a calculated value of zero, which is what you observed.

Give this a try....if you still have troubles, please send all the input
files, and we will look into it.

..good luck..dac

-- 
==================================================================
David A. Case                     |  e-mail:      case.scripps.edu
Dept. of Molecular Biology, TPC15 |  fax:          +1-858-784-8896
The Scripps Research Institute    |  phone:        +1-858-784-9768
10550 N. Torrey Pines Rd.         |  home page:                   
La Jolla CA 92037  USA            |    http://www.scripps.edu/case
==================================================================
Received on Fri May 02 2003 - 18:53:02 PDT