Hi I'm running md with NMR bond restraints. Amber 7
stops after 14ps with the following message.
Interestingly, when I restart the job from the rst
file, amber stops at 35ps with the same effor message.
Is there a way the amber can recalculate the virtual
box periodically? Thanks. -Eric
Frac coord min, max: 8.23603576138125D-002
1.00001202699347
The system has extended beyond
the extent of the virtual box.
Restarting sander will recalculate
a new virtual box with 30 Angstroms
extra on each side, if there is a
restart file for this configuration.
EWALD BOMB in subroutine Routine: map_coords
(ew_force.f)
Atom out of bounds. If a restart has been written,
restarting should resolve the error
Input:
MD in-vacuo
&cntrl
irest=0, ntr=1,
igb = 0, ntb = 0, ntpr = 100, ntwx = 10,
cut = 10.0, nmropt=1,
tempi = 300.0, temp0 = 300.0, ntt = 1, tautp = 0.5,
imin = 0,vlimit=10
nstlim = 100000, dt = 0.001,
&end
&wt type='REST', istep1=0,istep2=0,value1=1.0,
value2=1.0,
&end
&wt type='END'
&end
DISANG=./DISANG
LISTOUT=POUT
END
END
DISANG:
&rst
iat=1,1, nstep1=1,nstep2=10000,
iresid=1,irstyp=0,ifvari=1,ninc=0,imult=0,ir6=0,ifntyp=0,
atnam='O04','C05',
r1=0.00000E+00,r2=2.130,r3=2.130,r4=5.00,
rk2=9999.0,rk3=9999.0,
r1a=0.00000E+00,r2a=2.130,r3a=2.130,r4a=5.00,
rk2a=9999.0,rk3a=9999.0,
&end
&rst
iat=1,1, nstep1=1,nstep2=10000,
iresid=1,irstyp=0,ifvari=1,ninc=0,imult=0,ir6=0,ifntyp=0,
atnam='C01','C18',
r1=0.00000E+00,r2=2.04,r3=2.04,r4=5.00,
rk2=9999.0,rk3=9999.0,
r1a=0.00000E+00,r2a=2.04,r3a=2.04,r4a=5.00,
rk2a=9999.0,rk3a=9999.0,
&end
__________________________________________________
Do you Yahoo!?
Yahoo! Mail Plus - Powerful. Affordable. Sign up now.
http://mailplus.yahoo.com
Received on Tue Jan 07 2003 - 15:26:15 PST