Hi,
> imin=0, ntx=5, ntpr=500,ntwx=500,
> ntwe=500, ntcm=1, igb=2, dielc=1,
> cut = 14.0, nscm = 1,
^^^^^^^^^^
...You are using a hard cutoff for the Coulomb interaction,
this might be the source of all kinds of weird behavior.
> EELEC = 4195.5463 EHBOND = .0000 CONSTRAINT =
... the large fluctions of EELEC also seem to point to the cutoff (I
believe, experts correct me please :-).
I'd set the cutoff to a value larger than the largest diameter of your
system, nsnb to some large number (the pairlist doesn't need to be
updated in this case) and look what happens then.
hope it helps,
regards
Andreas
--
)))))
(((((
( O O )
-------oOOO--(_)--OOOo-----------------------------------------------------
o Wolfgang Andreas Svrcek-Seiler
o (godzilla)
svrci_at_tbi.univie.ac.at
.oooO Tel.:01-4277-52733
( ) Oooo.
-------\ (----( )--------------------------------------------------------
\_) ) /
(_/
From prbj_at_rediffmail.com 19 Sep 2002 17:27:48 -0000
Message-id: <20020919172748.28815.qmail.webmail26.rediffmail.com>
Date: 19 Sep 2002 17:27:48 -0000
From: Prem Raj <prbj_at_rediffmail.com>
To: AMBER list <amber.heimdal.compchem.ucsf.edu>
Subject: compiling without ISTAR2
In-Reply-to: <3D89F0D8.BE7268BE.ibpc.fr>
Dear Amber users,
I started a dynamics simulation on a protein molecule
with
explicit water using Amber 6 ( sander_classic). The system has a
total of
34800 atoms. when I ran the initail minimisation I got the below
error.
GROUP 8 HAS HARMONIC CONSTRAINTS 500.00000
GRP 8 RES 141 TO 157
Number of atoms in this group = 288
----- END OF GROUP READ -----
Ligand Grid: OFF (not requested)
Too many atoms for 16 bit pairlist -
Recompile without ISTAR2
In which file should I make these changes before I recompile the
software.
************************************************************
Prem Raj B. Joseph
Dept. of Chemistry and Biochemistry
Howard Hughes Medical Institute
University of Maryland Baltimore County
1000 Hilltop Circle, Baltimore, MD 21250
Ph: (410)455-2718
email: prbj123_at_rediffmail.com
Residence:
4747 Drayton Grn
Baltimore, MD - 21227
Ph(Res): (410)247-2413
*************************************************************
thanks in advance.