ewald bomb

From: Vlad Cojocaru <Vlad.Cojocaru_at_mpi-bpc.mpg.de>
Date: Fri 30 Aug 2002 15:38:49 +0200

Dear Amber users,
    I made the script below running but after a while (1000 steps there
is an EWALD bomb occures with the error message:
EWALD BOMB in subroutine ewald_list
  volume of ucell too big, too many subcells
  list grid memory needs to be reallocated, restart sander

Could somebody give me some advices about what I sould change to the script?
Thanks a lot..vlad



# MD with heating to 500K and then cooling down back to
300K
 &cntrl

                                                                               

  nmropt =
1,
  ntx = 7, irest = 1, ntrx = 1, ntxo =
1,
  ntpr = 50, ntwx = 100, ntwv = 0, ntwe =
0,
                                                                               

  ntf = 2, ntb =
2,
  cut = 9.0, nsnb =
10,
                                                                               

  ibelly = 0, ntr =
0,
                                                                               

  nstlim =
15000,
  nscm =
0,
  t = 0.0, dt =
0.001,
                                                                               

  tempi =
300.0,
  ig = 71277, heat =
0.0,
  ntt =
1,
                                                                               

  ntp = 1, pres0 =
1.0,
                                                                               

  ntc = 2, tol =
0.00001,
  
vlimit=15,

                                                                               

 &end

 &wt

   type='TEMP0', istep1=0,
istep2=1000,
                 value1=300.0,
value2=500.0,
 &end

 &wt

   type='TEMP0', istep1=1001,
istep2=3000,
                 value1=500.0,
value2=500.0,
 &end

 &wt

   type='TEMP0', istep1=3001,
istep2=15000,
                 value1=500.0,
value2=300.0,
 &end

 &wt

   type='TAUTP', istep1=0,
istep2=3000,
                 value1=0.2,
value2=0.2,
 &end

 &wt

   type='TAUTP', istep1=3001,
istep2=11000,
                 value1=4.0,
value2=2.0,
 &end

 &wt

   type='TAUTP', istep1=11001,
istep2=13000,
                 value1=1.0,
value2=1.0,
 &end

 &wt

   type='TAUTP', istep1=13001,
istep2=14000,
                 value1=0.5,
value2=0.5,
 &end

 &wt

   type='TAUTP', istep1=14001,
istep2=15000,
                 value1=0.05,
value2=0.05,
 &end

 &wt

   
type='END',
 &end

 &rst

   
iat=0,
 &end



-- 
Vlad Cojocaru 
Max Planck Institut for Biophysical Chemistry 
Deparment: 060 
Am Fassberg 11, 37077 Goettingen, Germany 
tel: ++49-551-201.1389 
e-mail: Vlad.Cojocaru_at_mpi-bpc.mpg.de  
Received on Fri Aug 30 2002 - 06:38:49 PDT