This is not a Compaq problem, we run the code all the time
on Alpha ev6 and ev67 machines without a problem. I suspect
that your system is not setup properly (really bad initial contacts).
Run 1 cycle of either Min or Md and check the energy. If it is
very high, check the initial structure.
jim
On Tue, 11 Jun 2002, lifang xu wrote:
> Dear Amber's users:
>
> I am running Sander on Compaq Alpha EV6 with Linux platform.
>
> In some initial runs, they are terminated with " Floating Invalid".
>
> The binary is compiled from source using FORTRAN compiler 'fort'.
>
> We thus recompiled the binary using an extra option -fpe3 to the compiler. This time the problems run until end. But with many quantities output by NaN and the final result is meaningless.
>
> I would appreciate it very much if any of you could tell me how to avoid or solve this " Floating" problem?
>
> Regards, Lifang Xu
>
>
----------------------------------------------------------------------------
James W. Caldwell (voice) 415-476-8603
Department of Pharmaceutical Chemistry (fax) 415-502-1411
Mail Stop 0446 (email) caldwell_at_heimdal.ucsf.edu
513 Parnassus Avenue
University of California
San Francisco, CA 94143-0446
----------------------------------------------------------------------------
Received on Tue Jun 11 2002 - 07:43:49 PDT